Yaskawa V1000
The Yaskawa V1000 is a world-class compact current vector drive that defines a new world standard. Demands for efficient production and better maintainability are on the rise, spurred by global competition. Yaskawa pays off the promise of being in control with products that make businesses move. The optimum balance of energy input, product output, maintenance risk, and long life is reached with Yaskawa. The V1000 provides a world of power in the palm of your hand!
Yaskawa V1000 1/8 – 25 HP
Features Highlights:
- Up to 30% smaller than the competition
- Current vector control, open loop
- RoHS compliance
- On-line tuning
- Induction motor (IM) or permanent magnet motor (PM) operation
- Function Block Diagram (FBD) programming via DriveWorksEZ™
- Side-by-side installation due to patented hybrid heatsink
- Removable terminal block with parameter backup function
- One-touch copy function with verify
- Super-fast 2 ms scan cycle with dual CPU
- EN954-1 Safety Cat. 3, Stop Cat. 0
- Increased vibration resistance, from 20 Hz to 50 Hz (0.65G)
- 1 in 10,000 failure rate
- Swing PWM function to decrease noise at low carrier frequencies
- Pre-maintenance function
- Modbus communication
- Cooling fan replacement without tools
- MTBF: 28 years
- Short Circuit Current Rating (SCCR): 30kA rms symmetrical
- Common programming with all other Yaskawa drives
- DriveWizard software available at no extra cost
The V1000 is the flagship drive of the V1000 Family, which also includes the V1000-4X.
Yaskawa V1000 Specification
ITEM
|
SPECIFICATION
|
---|---|
Overload Capacity | 150% Overload for 60 sec. (Heavy Duty) 120% Overload for 60 sec. (Normal Duty) |
Output Frequency | 0~400 Hz (higher frequencies available with custom software) |
Control Methods | Open Loop Current Vector Control, V/f Control, PM Open Loop Vector Control Simple closed loop speed control available |
Protective Design | IP20/NEMA1 |
Braking Transistor | Standard in all models |
Braking Torque | 20 – 40% increase with intelligent high-slip braking function |
KEB Function | Uses mechanical energy to continue operation during momentary power failure, standard |
Overvoltage Function | Prevention function for die-cushion in a hydraulic mechanical press and other applications |
Maintenance | Elapsed timer assists in preventative maintenance for cooling fan, capacitors, and transistors Easily replaceable cooling fan |
Global Certification | CE, UL, cUL, RoHS, TUV |
Available I/O | (7) multi-function digital inputs (1) hardwire baseblock (2) multi-function analog inputs (1) multi-function pulse input (1) multi-function relay output (2) multi-function photo-coupler outputs (1) multi-function 0-10 Vdc analog output (1) multi-function pulse output |
Network Communication | Standard: RS-422/485 MODBUS 115 kbpsOptional: DeviceNet, EtherCAT, EtherNet/IP, MECHATROLINK-II, MECHATROLINK-III, Modbus TCP/IP, PROFIBUS-DP, PROFINET |
Keypad Operator | Standard LED 5 digit display
Optional multi-lingual, full-text remote LCD |
Yaskawa V1000 asia Models & Ratings
Yaskawa V1000 200-240V, 1-Phase
DRIVE MODEL NUMBER | NORMAL DUTY1 | HEAVY DUTY1 | STANDARD ENCLOSURE | ||
---|---|---|---|---|---|
RATED OUTPUT CURRENT (AMPS) |
NOMINAL HP2 | RATED OUTPUT CURRENT (AMPS) |
NOMINAL HP2 | ||
CIMR-VTBA0001FAA | 1.2 | 1/8 & 1/4 | 0.8 | 1/8 | NEMA 1 |
CIMR-VTBA0002FAA | 1.9 | 1/4 | 1.6 | 1/4 | |
CIMR-VTBA0003FAA | 3.3 | 1/2 & 3/4 | 3.0 | 1/2 | NEMA 1 |
CIMR-VTBA0006FAA | 6.0 | 1 | 5.0 | 3/4 & 1 | |
CIMR-VTBA0010FAA | 9.6 | 2 & 3 | 8.0 | 2 | NEMA 1 |
CIMR-VTBA0012FAA | 12.0 | 3 | 11.0 | 3 | |
CIMR-VTBA0018FAA | 17.5 | 5 | 17.5 | 5 |
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on 230 Volt and 460 Volt Induction-Type Squirrel Cage NEMA B 4-Pole Motors as represented in NEC Table 430.250 Full-Load Current, Three-Phase Alternating-Current Motors.
Yaskawa V1000 200-240V, 3-Phase
DRIVE MODEL NUMBER | NORMAL DUTY1 | HEAVY DUTY1 | STANDARD ENCLOSURE | ||
---|---|---|---|---|---|
RATED OUTPUT CURRENT (AMPS) |
NOMINAL HP2 | RATED OUTPUT CURRENT (AMPS) |
NOMINAL HP2 | ||
CIMR-VT2A0001FAA | 1.2 | 1/8 & 1/4 | 0.8 | 1/8 | NEMA 1 |
CIMR-VT2A0002FAA | 1.9 | 1/4 | 1.6 | 1/4 | |
CIMR-VT2A0004FAA | 3.5 | 1/2 & 3/4 | 3.0 | 1/2 | |
CIMR-VT2A0006FAA | 6.0 | 1 | 5.0 | 3/4 & 1 | NEMA 1 |
CIMR-VT2A0010FAA | 9.6 | 2 & 3 | 8.0 | 2 | |
CIMR-VU2A0012FAA | 12 | 3 | 11.0 | 3 | |
CIMR-VU2A0020FAA | 19.6 | 5 | 17.5 | 5 | NEMA 1 |
CIMR-VT2A0030FAA | 30 | 7.5 & 10 | 25 | 7.5 | |
CIMR-VT2A0040FAA | 40 | 10 | 33 | 10 | |
CIMR-VT2A0056FAA | 56 | 20 | 47 | 15 | NEMA 1 |
CIMR-VT2A0069FAA | 69 | 25 | 60 | 20 |
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on 230 Volt and 460 Volt Induction-Type Squirrel Cage NEMA B 4-Pole Motors as represented in NEC Table 430.250 Full-Load Current, Three-Phase Alternating-Current Motors.
Yaskawa V1000 380-480V 3-Phase
DRIVE MODEL NUMBER | NORMAL DUTY1 | HEAVY DUTY1 | STANDARD ENCLOSURE | ||
---|---|---|---|---|---|
RATED OUTPUT CURRENT (AMPS) |
NOMINAL HP2 | RATED OUTPUT CURRENT (AMPS) |
NOMINAL HP2 | ||
CIMR-VT4A0001FAA | 1.2 | 1/2 | 1.2 | 1/2 | NEMA 1 |
CIMR-VT4A0002FAA | 2.1 | 3/4 & 1 | 1.8 | 3/4 | |
CIMR-VT4A0004FAA | 4.1 | 2 | 3.4 | 1 & 2 | NEMA 1 |
CIMR-VT4A0005FAA | 5.4 | 3 | 4.8 | 3 | |
CIMR-VT4A0007FAA | 6.9 | 4 | 5.5 | 3 | NEMA 1 |
CIMR-VT4A0009FAA | 8.8 | 5 | 7.2 | 4 | |
CIMR-VT4A0011FAA | 11.1 | 7.5 | 9.2 | 5 | NEMA 1 |
CIMR-VT4A0018FAA | 17.5 | 10 | 14.8 | 7.5 & 10 | |
CIMR-VT4A0023FAA | 23 | 15 | 18 | 10 | NEMA 1 |
CIMR-VT4A0031FAA | 31 | 20 | 24 | 15 | |
CIMR-VT4A0038FAA | 38 | 25 | 31 | 20 |
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on 230 Volt and 460 Volt Induction-Type Squirrel Cage NEMA B 4-Pole Motors as represented in NEC Table 430.250 Full-Load Current, Three-Phase Alternating-Current Motors.
Yaskawa V1000 EU Models & Ratings
Yaskawa V1000 200-240V, 1-Phase
DRIVE MODEL NUMBER | NORMAL DUTY1 | HEAVY DUTY1 | STANDARD ENCLOSURE | ||
---|---|---|---|---|---|
RATED OUTPUT CURRENT (AMPS) |
NOMINAL HP2 | RATED OUTPUT CURRENT (AMPS) |
NOMINAL HP2 | ||
CIMR-VCBA0001FAA | 1.2 | 1/8 & 1/4 | 0.8 | 1/8 | NEMA 1 |
CIMR-VCBA0002FAA | 1.9 | 1/4 | 1.6 | 1/4 | |
CIMR-VCBA0003FAA | 3.3 | 1/2 & 3/4 | 3.0 | 1/2 | NEMA 1 |
CIMR-VCBA0006FAA | 6.0 | 1 | 5.0 | 3/4 & 1 | |
CIMR-VCBA0010FAA | 9.6 | 2 & 3 | 8.0 | 2 | NEMA 1 |
CIMR-VCBA0012FAA | 12.0 | 3 | 11.0 | 3 | |
CIMR-VCBA0018FAA | 17.5 | 5 | 17.5 | 5 |
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on 230 Volt and 460 Volt Induction-Type Squirrel Cage NEMA B 4-Pole Motors as represented in NEC Table 430.250 Full-Load Current, Three-Phase Alternating-Current Motors.
Yaskawa V1000 200-240V, 3-Phase
DRIVE MODEL NUMBER | NORMAL DUTY1 | HEAVY DUTY1 | STANDARD ENCLOSURE | ||
---|---|---|---|---|---|
RATED OUTPUT CURRENT (AMPS) |
NOMINAL HP2 | RATED OUTPUT CURRENT (AMPS) |
NOMINAL HP2 | ||
CIMR-VC2A0001FAA | 1.2 | 1/8 & 1/4 | 0.8 | 1/8 | NEMA 1 |
CIMR-VC2A0002FAA | 1.9 | 1/4 | 1.6 | 1/4 | |
CIMR-VC2A0004FAA | 3.5 | 1/2 & 3/4 | 3.0 | 1/2 | |
CIMR-VC2A0006FAA | 6.0 | 1 | 5.0 | 3/4 & 1 | NEMA 1 |
CIMR-VC2A0010FAA | 9.6 | 2 & 3 | 8.0 | 2 | |
CIMR-VC2A0012FAA | 12 | 3 | 11.0 | 3 | |
CIMR-VC2A0020FAA | 19.6 | 5 | 17.5 | 5 | NEMA 1 |
CIMR-VC2A0030FAA | 30 | 7.5 & 10 | 25 | 7.5 | |
CIMR-VC2A0040FAA | 40 | 10 | 33 | 10 | |
CIMR-VC2A0056FAA | 56 | 20 | 47 | 15 | NEMA 1 |
CIMR-VC2A0069FAA | 69 | 25 | 60 | 20 |
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on 230 Volt and 460 Volt Induction-Type Squirrel Cage NEMA B 4-Pole Motors as represented in NEC Table 430.250 Full-Load Current, Three-Phase Alternating-Current Motors.
Yaskawa V1000 380-480V 3-Phase
DRIVE MODEL NUMBER | NORMAL DUTY1 | HEAVY DUTY1 | STANDARD ENCLOSURE | ||
---|---|---|---|---|---|
RATED OUTPUT CURRENT (AMPS) |
NOMINAL HP2 | RATED OUTPUT CURRENT (AMPS) |
NOMINAL HP2 | ||
CIMR-VC4A0001FAA | 1.2 | 1/2 | 1.2 | 1/2 | NEMA 1 |
CIMR-VC4A0002FAA | 2.1 | 3/4 & 1 | 1.8 | 3/4 | |
CIMR-VC4A0004FAA | 4.1 | 2 | 3.4 | 1 & 2 | NEMA 1 |
CIMR-VC4A0005FAA | 5.4 | 3 | 4.8 | 3 | |
CIMR-VC4A0007FAA | 6.9 | 4 | 5.5 | 3 | NEMA 1 |
CIMR-VC4A0009FAA | 8.8 | 5 | 7.2 | 4 | |
CIMR-VC4A0011FAA | 11.1 | 7.5 | 9.2 | 5 | NEMA 1 |
CIMR-VC4A0018FAA | 17.5 | 10 | 14.8 | 7.5 & 10 | |
CIMR-VC4A0023FAA | 23 | 15 | 18 | 10 | NEMA 1 |
CIMR-VC4A0031FAA | 31 | 20 | 24 | 15 | |
CIMR-VC4A0038FAA | 38 | 25 | 31 | 20 |
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on 230 Volt and 460 Volt Induction-Type Squirrel Cage NEMA B 4-Pole Motors as represented in NEC Table 430.250 Full-Load Current, Three-Phase Alternating-Current Motors.
Yaskawa V1000 USA Models & Ratings
Yaskawa V1000 200-240V, 1-Phase
DRIVE MODEL NUMBER | NORMAL DUTY1 | HEAVY DUTY1 | STANDARD ENCLOSURE | ||
---|---|---|---|---|---|
RATED OUTPUT CURRENT (AMPS) |
NOMINAL HP2 | RATED OUTPUT CURRENT (AMPS) |
NOMINAL HP2 | ||
CIMR-VUBA0001FAA | 1.2 | 1/8 & 1/4 | 0.8 | 1/8 | NEMA 1 |
CIMR-VUBA0002FAA | 1.9 | 1/4 | 1.6 | 1/4 | |
CIMR-VUBA0003FAA | 3.3 | 1/2 & 3/4 | 3.0 | 1/2 | NEMA 1 |
CIMR-VUBA0006FAA | 6.0 | 1 | 5.0 | 3/4 & 1 | |
CIMR-VUBA0010FAA | 9.6 | 2 & 3 | 8.0 | 2 | NEMA 1 |
CIMR-VUBA0012FAA | 12.0 | 3 | 11.0 | 3 | |
CIMR-VUBA0018FAA | 17.5 | 5 | 17.5 | 5 |
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on 230 Volt and 460 Volt Induction-Type Squirrel Cage NEMA B 4-Pole Motors as represented in NEC Table 430.250 Full-Load Current, Three-Phase Alternating-Current Motors.
Yaskawa V1000 200-240V, 3-Phase
DRIVE MODEL NUMBER | NORMAL DUTY1 | HEAVY DUTY1 | STANDARD ENCLOSURE | ||
---|---|---|---|---|---|
RATED OUTPUT CURRENT (AMPS) |
NOMINAL HP2 | RATED OUTPUT CURRENT (AMPS) |
NOMINAL HP2 | ||
CIMR-VU2A0001FAA | 1.2 | 1/8 & 1/4 | 0.8 | 1/8 | NEMA 1 |
CIMR-VU2A0002FAA | 1.9 | 1/4 | 1.6 | 1/4 | |
CIMR-VU2A0004FAA | 3.5 | 1/2 & 3/4 | 3.0 | 1/2 | |
CIMR-VU2A0006FAA | 6.0 | 1 | 5.0 | 3/4 & 1 | NEMA 1 |
CIMR-VU2A0010FAA | 9.6 | 2 & 3 | 8.0 | 2 | |
CIMR-VU2A0012FAA | 12 | 3 | 11.0 | 3 | |
CIMR-VU2A0020FAA | 19.6 | 5 | 17.5 | 5 | NEMA 1 |
CIMR-VU2A0030FAA | 30 | 7.5 & 10 | 25 | 7.5 | |
CIMR-VU2A0040FAA | 40 | 10 | 33 | 10 | |
CIMR-VU2A0056FAA | 56 | 20 | 47 | 15 | NEMA 1 |
CIMR-VU2A0069FAA | 69 | 25 | 60 | 20 |
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on 230 Volt and 460 Volt Induction-Type Squirrel Cage NEMA B 4-Pole Motors as represented in NEC Table 430.250 Full-Load Current, Three-Phase Alternating-Current Motors.
Yaskawa V1000 380-480V 3-Phase
DRIVE MODEL NUMBER | NORMAL DUTY1 | HEAVY DUTY1 | STANDARD ENCLOSURE | ||
---|---|---|---|---|---|
RATED OUTPUT CURRENT (AMPS) |
NOMINAL HP2 | RATED OUTPUT CURRENT (AMPS) |
NOMINAL HP2 | ||
CIMR-VU4A0001FAA | 1.2 | 1/2 | 1.2 | 1/2 | NEMA 1 |
CIMR-VU4A0002FAA | 2.1 | 3/4 & 1 | 1.8 | 3/4 | |
CIMR-VU4A0004FAA | 4.1 | 2 | 3.4 | 1 & 2 | NEMA 1 |
CIMR-VU4A0005FAA | 5.4 | 3 | 4.8 | 3 | |
CIMR-VU4A0007FAA | 6.9 | 4 | 5.5 | 3 | NEMA 1 |
CIMR-VU4A0009FAA | 8.8 | 5 | 7.2 | 4 | |
CIMR-VU4A0011FAA | 11.1 | 7.5 | 9.2 | 5 | NEMA 1 |
CIMR-VU4A0018FAA | 17.5 | 10 | 14.8 | 7.5 & 10 | |
CIMR-VU4A0023FAA | 23 | 15 | 18 | 10 | NEMA 1 |
CIMR-VU4A0031FAA | 31 | 20 | 24 | 15 | |
CIMR-VU4A0038FAA | 38 | 25 | 31 | 20 |
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on 230 Volt and 460 Volt Induction-Type Squirrel Cage NEMA B 4-Pole Motors as represented in NEC Table 430.250 Full-Load Current, Three-Phase Alternating-Current Motors.See more product please click here
Trở lại mục biến tần
Trở lại mục biến tần yaskawa
Các sản phẩm khác
Tham khảo thêm các sản phẩm khác tại asiame
Công ty cổ phần cơ điện asia
Công ty Cổ Phần Cơ Điện Asia (ASIAME JSC) chuyên cung cấp sản phẩm và dịch vụ liên quan tới ngành cơ điện tự động hóa
Các sản phẩm phân phối kinh doanh chính :
- Biến tần Yaskawa Nhật Bản
- Robot công nghiệp Yaskawa Nhật Bản
- Biến tần một chiều- DC driver- Sprint Electric- Italia
- Máy biến áp FUJI- Nhật Bản
- Động cơ thường và động cơ hộp số Mitsubishi- Nhật Bản
- Hóa chất giảm điện trở đất, sử dụng trong các hệ thống tiếp địa.
Với đội ngũ quản lý kỹ sư chuyên nghiệp nhiều kinh nghiệm đông đảo kỹ thuật viên công nhân lành nghề Công ty Cổ Phần Cơ Điện Asia luôn đáp ứng được đa dạng yêu cầu từ Quý khách hàng với chất lượng tốt nhất.
Chúng tôi luôn luôn nỗ lực cải tiến hoàn thiện hệ thống để mang lại cho khách hàng những sản phẩm và dịch vụ tốt nhất, mục tiêu của chúng tôi luôn luôn lấy sự hài lòng của khách hàng làm nền tảng cho sự phát triển bền vững.
Chúng tôi trân trọng cảm ơn Quý khách hàng đã quan tâm và sử dụng sản phẩm dịch vụ của chúng tôi và mong muốn đồng hành cùng sự phát triển của Quý khách hàng
Trân trọng cảm ơn.
Đánh giá
Chưa có đánh giá nào.