Lỗi máy CNC Fadal

Lỗi máy CNC Fadal

Lỗi máy CNC Fadal Fadal PLC Alarms List / PLC Messages for Fadal Machining Centers (GE FANUC 0i MC CNC Controls).

Lỗi máy CNC Fadal

Lỗi máy CNC Fadal PLC Alarms

ALARM DESCRIPTION
1002 DUAL DOOR SWITCH FAILURE
1003 M02 POWER SAVE, RESET TO CLEAR
1005 DOOR OPEN, MDI TOOL CHG ALRM
1016 TOOL LIFE END REPLACE TOOL AND RESET ON TOOL LIFE SCREEN
1040 CAN NOT CHANGE TOOL WHEN SPINDLE IS RUNNNG
1041 CAN NOT CHANGE TOOL WHEN Z IS NOT IN HOME POSITION
1042 CAN NOT CHANGE TOOL WHEN SPINDEL IS NOT ORIENTED
1050 INIT SHIFT FAIL, CYC STRT INHIBT
1051 LOST LOW GEAR DURING OPERATION
1052 LOST HIGH GEAR DURING OPERATION
1054 HIGH TO LOW GEAR SHIFT FAILED
1055 LOW TO HIGH GEAR SHIFT FAILED
1056 SPINDLE WINDING SHIFT FAILED
1081 M11 ALM, RETURN/CLR SPDL TOOL
1083 TOOL UP AT MACHINE ON FAILED
1084 TOOL UP AT DRUM ROTATION FAILED
1086 STORED TOOL ILLEGAL, SEE OPR MSG
1090 NO EMPTY TOOL POCKETS AVAILABLE
1091 INVALID TOOL MGMT DATA FOR SEARCH
1092 OPTIONAL TOOL MGMT SEARCH ILLEGAL
1093 EMPTY POT SEARCH ILLEGAL DATA
1094 EMPTY POT SEARCH INVALID OPT
1095 TOOL MGMT SEARCH PROTECTED
1096 TOOL CHANGER INIT FAULT, SEE MSG
1097 NO TOOL CHGR, CYC STRT INHIBITED
1103 ATC CAN’T EXTEND DURING SP-OP
1104 ATC TOOL COUNT SWITCH MISSING
1105 INHIBIT SPINDLE CMM, ATC IS NOT AT HOME POS.
1106 ATC Z AXIS IS NOT AT REF.POSTION PLEASE REFERENCE Z AXIS
1107 ATC SPINDLE IS NOT ORIENTED. PLEASE ORIENT THE SPINDLE
1110 ATC CAROUSEL EXTEND FAILED
1111 ATC CAROUSEL RETRACT FAILED
1112 ATC CAROUSEL E-STOP ALARM
1113 ATC SLIDE SENSORS ARE BAD
1114 ATC SLIDE STOP IN WRONG PLACE AND TIME OUT
1115 ATC SLIDE EXTENDING IS TOO QUICK OR EXTEND SENSOR IS BAD
1116 ATC SLIDE RETRACTING IS TOO QUICK OR SLIDE HOME SENSOR IS BAD
1117 ATC SLIDE CAN NOT RETRACT BECAUSE DRAW BAR IS OPEN
1120 M85 WINDOW R/W DATA ERROR
1120 M86 WINDOW R/W DATA ERROR
1120 M87 WINDOW R/W DATA ERROR
1120 M88 WINDOW R/W DATA ERROR
1125 DRAW BAR TIME OUT CHECK DRAW BAR SENSOR
1126 ORIENTATION INHIBIT, SLIDE EXTENDED
1130 4TH AXS BRAKE ON, COMMAND HALTED
1132 5TH AXS BRAKE ON, COMMAND HALTED
1134 INCH METRIC CONVERSIO ERROR CHANGE MODE IN SETTINGS SCREEN
1143 CYCLE CNC POWER
1145 DOOR PARAMETER WRITE ALARM
1147 ILLEGAL TOOL SEE MESSAGE
1152 ATC DISK IS IN WRONG POSITION.
1153 CAN NOT EXTEND ATC WHEN ATC IS MOVING
1154 CAN NOT MOVE Z AXIS WHEN ATC IS RUNNING
1163 CYCLE START IS INHIBITED
1166 M11 RESET ACTIVE
1170 M84 LOGR CALIB DATA ZERO ERROR
1171 M84 LOGR SPDL SPEED CALC ERROR
1172 M84 LOW GEAR SHIFT ERROR
1173 M84 LOGR WINDR READ SAMPLE ERROR
1174 M84 LOGR ARBITRARY DATA ERROR
1175 M84 LOGR REV COUNT WINDR ERROR
1176 M84 LOGR FDBK COUNT WINDR ERROR
1177 M84 LOGR DATA OUT OF RANGE ERROR
1180 M84 LOGR DISP RATIO MATH ERROR
1181 M84 LOGR RATIO RANGE ERROR
1182 M84 LOGR WINDW PAR SET ERROR 1
1183 M84 LOGR WINDW PAR SET ERROR 2
1184 M84 LOGR CALIB SPDL START ERROR
1186 M84 BELT CALIB CYCLE INHIBITED
1190 M84 HIGR CALIB DATA ZERO ERROR
1191 M84 HIGR SPDL SPEED CALC ERROR
1192 M84 HIGH GEAR SHIFT ERROR
1193 M84 HIGR WINDR READ SAMPLE ERROR
1194 M84 HIGR ARBITRARY DATA ERROR
1195 M84 HIGR REV COUNT WINDR ERROR
1196 M84 HIGR FDBK COUNT WINDR ERROR
1197 M84 HIGR DATA OUT OF RANGE ERROR
1200 M84 HIGR DISP RATIO MATH ERROR
1201 M84 HIGR RATIO RANGE ERROR
1202 M84 HIGR WINDW PAR SET ERROR 1
1203 M84 HIGR WINDW PAR SET ERROR 2
1204 M84 HIGR CALIB SPDL START ERROR
1205 NEED TO REFERENCE ALL AXES FIRST
1206 DOOR OPEN/CLOSE REQUIRED
1210 M84 #3741 CALC ERROR
1211 M84 #3742 CALC ERROR
1212 M84 MAX LOW WINDW ERROR
1213 M84 MAX HI WINDW ERROR
1214 M84 #3751 CALC ERROR
1215 M84 SHIFT SPD WINDW ERROR
1216 M84 #3736 CALC ERROR
1217 M84 #3736 WINDW ERROR
1220 M84 #3752 WINDW ERROR
1221 M84 #3762 WINDW ERROR

Lỗi máy CNC Fadal PLC Messages

MESSAGE DESCRIPTION
2004 OPERATOR FUNCTION INHIBITED CHECK DOOR ALM OPERATIONAL MODE
2005 MACHINE DOOR OPEN. FEEDHOLD ON. CYCLE START IS INHIBITED
2006 DOOR OVERRIDE IS ACTIVE
2007 CLOSE MACHINE DOOR TO CONTINUE OR RESET TO CANCEL OPERATION
2010 USE FUNC + SPINDLE CW OR CCW PB TO RESTART SPINDLE
2011 PRESS CYCLE START TO RESUME PROGRAM COMMAND
2012 TOOL CHANGE INTERUPTED BY DOOR OPEN.
2013 PRESS CYCLE START TO RESTART TOOL CHANGE
2014 EXIT PROGRAM RESTART BEFORE CYCLE START
2015 DOOR UNLOCK INHIBITED
2016 TOOL CAGE DOOR IS OPEN, PLEASE CLOSE IT. FEED HOLD IS ON
2019 RESET E-STOP WITH ALARM PB.
2020 LOW LUBE OIL LEVEL REFILL VACTRA-2 OR EQUIVALENT
2021 TOOL LIFE NEAR END OR HAS EXPIRED
2023 TOOL DATA SWAP ERROR CHECK TOOL LOCATION
2024 LOW PROBE BATTERY
2026 AIR-OIL FAULT, ILLEGAL TABLE DATA FOR AIR-OIL INTERVALS
2027 AIR-OIL FAULT FEEDHOLD/SPINDLE STOP FORCED.SEE OTHER MESSAGES
2030 AIR-OIL LOW OIL PRESSURE FAULT
2031 AIR-OIL UPPER BEARING PRESSURE FAILED FAULT
2032 AIR-OIL LOWER BEARING PRESSURE FAILED FAULT
2033 AIR-OIL HIGH OIL PRESSURE WHILE PUMP TURNED OFF
2034 AIR-OIL FAULT. SAFELY STOP MACHINE, OR STOP WILL BE FORCED
2035 AIR-OIL SPINDLE AIR/VAC PRESSURE FAILED FAULT
2036 AIR-OIL OIL LEVEL LOW PLEASE REFILL RESEVOIR
2037 CORRECT FAULT & USE ALARM-MSG PBTO RESET ALL AIR-OIL MESSAGE’S
2044 TOOL ARM OVERLOAD TRIP MAINTENANCE MUST RESET OVERLOAD
2045 TOOL MAGAZINE OVERLOAD TRIP MAINTENANCE MUST RESET OVERLOAD
2046 WASHDOWN PUMP OVERLOAD TRIP MAINTENANCE MUST RESET OVERLOAD
2055 M11 MSG, ATC IS SET POCKET 1
2056 M11 ALM, USING FUNC+LOAD TOOL BUTTON TO RETURN SPDL TOOL TO ATC FIRST
2057 PWR DOWN REQ’D TO CLR ALRM 1050 CHECK AIR PRESSURE 80-90 PSI
2058 M11 ALM, TAKE SPDL TOOL OFF, CLR SPDL TOOL MANAGMENT TO 0
2059 M11 ALM, OPERATOR MUST EDIT TOOL MANAGEMENT ACCORDING TO REAL CAROUSEL
2060 Z AXIS TOOL CHANGE PROX SWITCH NOT CONFIRMING TOOL CHANGE POSN
2061 TOOL DRUM POT NOT UP FOR ROTATION OF TOOL DRUM
2062 TOOL DRUM POT NOT IN DOWN POSN FOR ACCESS BY TOOL ARM
2063 TOOL ARM NOT IN POSITION FOR TOOL REMOVAL FROM SPNDLE
2064 DRAWBAR NOT RELEASED FOR REMOVAL OF TOOL FROM SPNDLE
2065 TOOL ARM NOT IN POSITION FOR TOOL INSERTION INTO SPNDLE
2066 DRAWBAR NOT CLAMPED ON NEW TOOL IN SPNDLE
2067 TOOL ARM NOT RETURNED TO PARK POSN AT END OF TOOL CHANGE
2068 USING “FUNC+CYCLE START” BUTTON TO RESTART MAGAZINE
2070 TOOL CHANGE COMMAND ABORTED TOOL CHANGE SERVICE MODE ACTIVE
2071 TOOL CHANGE COMMAND ABORTED SPINDLE FWD, REV, ORIENT ACTIVE
2072 ARM NOT AT HOME POSITION
2073 ARM AT SPINDLE
2074 Z MOVE TO THE PROHIBIT AREA
2075 TOOL CHNG & SPNDL, E-STOP FORCED ALARM PB TO CLEAR
2076 TOOL CHANGE SERVICE MODE SET
2077 TOOL CHNG ALARM, ALARM PB TO CLR CYCLE START INHIBITED
2080 DATC IS NOT AT HOME POS. CYCLE START INHIBITED
2082 TOOL DRUM AT POCKET # OF # PRESS DRUM PSN TO CLEAR MSG
2087 STORED TOOL VALUE OF # IS NOT IN LEGAL RANGE OF 1 TO #(maximum tool number)
2100 NO TOOL CHANGER SELECTED CORRECT K5.X & CYCLE POWER
2101 ILLEGAL VMC TOOL CHANGR SETTING CORRECT K5.X & CYCLE POWER
2102 VMC & HMC TOOL CHANGER BOTH SET CORRECT K5.X & CYCLE POWER
2127 ORIENTATION INHIBIT, SLIDE EXTENDED
2130 LOW COOLANT LEVEL OR PUMP FAILURE
2131 USE M61 TO RELEASE 4TH AX BRAKE PRIOR TO AXIS COMMAND BLOCK
2133 USE M62 TO RELEASE 5TH AX BRAKE PRIOR TO AXIS COMMAND BLOCK
2136 POSSIBLE FAILURE OF PCB-0321 OR SPINDLE BELT MAY BE BROKEN
2137 POSSIBLE FAILURE OF PCB-0321
2140 AXIS INHIBIT BY MIDACO PALLET CHANGER
2142 DOOR IS CLOSED. PRESS ALARM PB TO RESET
2150 ATC IS NOT AT HOME POSITION USE M186 RETURN;Z INHIBITED
2151 NEW TOOL VALUE OF # IS NOT IN LEGAL RANGE OF #(minimum tool value) TO (maximum tool value).
2165 PRESS UNLOCK BUTTON FOR 60S TO UNLOCK DOOR
2187 M84 BELT CALIBRATION ACTIVE
2222 IO OUTPUT OVERCURRENT
2224 PB TWICE TO RESET, THEN USE JOG OR HANDLE MODE TO MOVE AXIS
2225 PRESS AND HOLD ENABLE KEY ONTHE BACK OF HMOP AND PRESS ALARM
2667 WINDOW WRITE ERROR, CE

 